top of page
100 Mtrs SOLAR CABLE 10 Sq mm - UV Resistant (KEI)

100 Mtrs SOLAR CABLE 10 Sq mm - UV Resistant (KEI)

₹14,000.00Price

KEI PV Solar cables are designed for connecting photovoltaic power supply systems.They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of a 1.5kV. These cables can be used indoor & outdoor for flexible and fixed installations with high mechanical strength in extreme weather conditions. cables are designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated photovoltaic installation.

 

Applications

These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 years under normal usage conditions.

 

Design

  • Conductor – Flexible Electrolytic Tinned fine copper strands, acc. To IEC 60228, class 5
  • Insulation – Crosslinked Halogen Free & Flame Retardant Insulation , Colour : White , Red Or Black
  • Outer Sheath – Crosslinked Halogen Free & Flame Retardant UV and ozone resistant Sheath in Black Or Black with Red Stri

 

Electrical Properties

  • Rated DC Voltage: 1.5 kV
  • Rated DC Voltage: 1.5 kV
  • Maximum Permitted DC Voltage: 1.8 kV
  • Maximum Permitted AC Voltage: 1 kV
  • Spark Test: 6000 Vac (8400 Vdc)
  • Voltage Withstand: 6.5 kV Ac & 15 kV dc

 

Thermal Characteristics

  • Ambient Temperature: -40°C ~ +90°C
  • Maximum Temperature at Conductor: 120°C (20000h)
  • Short Circuit Temperature: 200°C (at conductor max. 5sec)
  • Thermal Endurance Test : According to EN 60216-2 (temperature index +120°C)

 

Chemical Characteristics

  • Mineral Oil Resistance: according to EN 60811-2-1
  • Ozone Resistance: according to EN 50396 part 8.1.3 Method B
  • Very good resistance to oil and chemicals
  • Acid & Alkaline Resistance: According to EN 60811-2-1
    (Oxal acid and sodium hydroxide)

 

Mechanical Characteristics

  • Minimum Bending Radius : 6 x OD (fixed), 15 x OD (occasional flexing)
  • Dynamic Penetration: According to requirement of Cables for PV systems
  • Tensile Strength: 6.5 N/mm2 for insulation and 8 N/mm2 for sheathing – according to EN60811
    • Weathering-UV Resistance
    • Resistance to fire
      • Acc. to EN 50618, Table 2
      • Single Cable Flame Test: EN 60332-1-2
      • Low Smoke Emission: EN 61034-2 (Light Transmittance > 70%)
      • Halogen-free per EN 50525-1, Annex B.

     

     

    Applications

    These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 years under normal usage conditions.

    Design

    • Conductor – Flexible Electrolytic Tinned fine copper strands, acc. To IEC 60228, class 5
    • Insulation – Crosslinked Halogen Free & Flame Retardant Insulation , Colour : White , Red Or Black
    • Outer Sheath – Crosslinked Halogen Free & Flame Retardant UV and ozone resistant Sheath in Black Or Black with Red Stri

    Electrical Properties

    • Rated DC Voltage: 1.5 kV
    • Rated DC Voltage: 1.5 kV
    • Maximum Permitted DC Voltage: 1.8 kV
    • Maximum Permitted AC Voltage: 1 kV
    • Spark Test: 6000 Vac (8400 Vdc)
    • Voltage Withstand: 6.5 kV Ac & 15 kV dc

    Thermal Characteristics

    • Ambient Temperature: -40°C ~ +90°C
    • Maximum Temperature at Conductor: 120°C (20000h)
    • Short Circuit Temperature: 200°C (at conductor max. 5sec)
    • Thermal Endurance Test : According to EN 60216-2 (temperature index +120°C)

    Chemical Characteristics

    • Mineral Oil Resistance: according to EN 60811-2-1
    • Ozone Resistance: according to EN 50396 part 8.1.3 Method B
    • Very good resistance to oil and chemicals
    • Acid & Alkaline Resistance: According to EN 60811-2-1
      (Oxal acid and sodium hydroxide)

    Mechanical Characteristics

    • Minimum Bending Radius : 6 x OD (fixed), 15 x OD (occasional flexing)
    • Dynamic Penetration: According to requirement of Cables for PV systems
    • Tensile Strength: 6.5 N/mm2 for insulation and 8 N/mm2 for sheathing – according to EN60811
    • Weathering-UV Resistance
    • Resistance to fire
      • Acc. to EN 50618, Table 2
      • Single Cable Flame Test: EN 60332-1-2
      • Low Smoke Emission: EN 61034-2 (Light Transmittance > 70%)
      • Halogen-free per EN 50525-1, Annex B.
    secure single phase.jpg
    Home UPS ECOVOLT SINE 1550 LUMINOUS

    ₹9,600.00

    secure single phase.jpg
    Home UPS ICON 1100+ LUMINOUS

    ₹11,600.00

    secure single phase.jpg
    LUMINOUS C10 Solar Battery - 100AH (5 Year Warranty)

    ₹13,350.00

    secure single phase.jpg
    LUMINOUS NXG 1850 SOLAR INVERTER - 24V

    ₹12,460.00

    secure single phase.jpg
    LUMINOUS POLY SOLAR PANEL - 12V / 170W

    ₹7,000.00

    secure single phase.jpg
    LUMINOUS TUBULAR BATTERY 100AH ILST12042

    ₹10,100.00

    secure single phase.jpg
    LUMINOUS TUBULAR BATTERY 110AH SC12054

    ₹12,400.00

    secure single phase.jpg
    LUMINOUS TUBULAR BATTERY 120AH RC15000

    ₹10,800.00

    secure single phase.jpg
    SOLAR RETROFIT -SRS SINE 4850- 50A / 48V

    ₹9,000.00

    RELATED PRODUCT YOU MIGHT NEED

    bottom of page